AMALGAM Series
WASTE WATER application and AQUACULTURE
25 .. 600 m3/hr – 110 .. 2641 GPM
Initial UV DOSE @ 40.000 µWsec/cm2
Against Cryptosporidium, Giardia, Poliovirus, Adenovirus, VHS, ISA, IPN
LCD control logic UV³ series or EBM cabinet
High efficiency amalgam UV-C lamp (14.000 hours lifespan)
High quality quartz sleeves
AISI 316 reactor
Sampling points
Horizontal or vertical installation
Standard or certified Ö_NORM / DVGW sensor optional
VERTICAL Series
HORIZONTAL Series
- 25,0 m3/hr - 110 GPM @ 40.000 µWsec/cm2
- 1 x 200W UV-C amalgam lamps (14.000 lifespan)
- 1190 mm maximum dimension
- 2" I/O connection
- High efficiency electronic ballast
- Standard Irradiance and Temperature sensor optional
- Certified Ö_NORM / DVGW sensor optional
- 4-20mA output optional
- Flanged connection optional
- EN 55022; EN 61000-3-2; EN 61000-4 compliance
- UV AM25 with control cabinet LCD display UV³
- 60,0 m3/hr - 264 GPM @ 40.000 µWsec/cm2
- 2 x 200W UV-C amalgam lamps (14.000 lifespan)
- 1190 mm maximum dimension
- DN80 I/O connection
- High efficiency electronic ballast
- Standard Irradiance and Temperature sensor optional
- Certified Ö_NORM / DVGW sensor optional
- 4-20mA output optional
- Flanged connection optional
- EN 55022; EN 61000-3-2; EN 61000-4 compliance
- UV AM60 with control cabinet LCD display UV³
- 90,0 m3/hr - 396 GPM @ 40.000 µWsec/cm2
- 3 x 200W UV-C amalgam lamps (14.000 lifespan)
- 1190 mm maximum dimension
- DN100 I/O connection
- High efficiency electronic ballast
- Standard Irradiance and Temperature sensor optional
- Certified Ö_NORM / DVGW sensor optional
- 4-20mA output optional
- Flanged connection optional
- EN 55022; EN 61000-3-2; EN 61000-4 conformità
- UV AM90 with control cabinet LCD display UV³
- 125,0 m3/hr - 550 GPM @ 40.000 µWsec/cm2
- 4 x 200W UV-C amalgam lamps (14.000 lifespan)
- 1190 mm maximum dimension
- DN150 I/O connection
- High efficiency electronic ballasts
- Standard Irradiance and Temperature sensor optional
- Certified Ö_NORM / DVGW sensor optional
- 4-20mA output optional
- Flanged connection optional
- EN 55022; EN 61000-3-2; EN 61000-4 compliance
- UV AM125 with control cabinet LCD display UV³
- 100 m3/hr - 440 GPM @ 40.000 µWsec/cm2
- 2 x 400W UV-C amalgam lamps (14.000 lifespan)
- 1800 mm maximum dimension
- DN100 I/O connection
- Sampling point
- Certified Ö_NORM / DVGW sensor optional
- 4-20 mA output optional
- EN 55022; EN 61000-3-2; EN 61000-4 compliance
- UV HM100 with EBM cabinet
- 250 m3/hr - 1100 GPM @ 40.000 µWsec/cm2
- 4 x 400W UV-C amalgam lamps (14.000 lifespan)
- 1800 mm maximun dimension
- DN200 I/O connection
- Sampling point
- Certified Ö_NORM / DVGW sensor optional
- 4-20 mA output optional
- EN 55022; EN 61000-3-2; EN 61000-4 compliance
- UV HM250 with EBM cabinet
- 400 m3/hr - 1761 GPM @ 40.000 µWsec/cm2
- 6 x 400W UV-C amalgam lamps (14.000 lifespan)
- 1800 mm maximum dimension
- DN250 I/O connection
- Sampling point
- Certified Ö_NORM / DVGW sensor optional
- 4-20 mA output optional
- EN 55022; EN 61000-3-2; EN 61000-4 compliance
- UV HM400 with EBM cabinet
- 600 m3/hr - 2642 GPM @ 40.000 µWsec/cm2
- 8 x 400W UV-C amalgam lamps (14.000 lifespan)
- 1800 mm maximum dimension
- DN250 I/O connection
- Sampling point
- Certified Ö_NORM / DVGW sensor optional
- 4-20 mA output optional
- EN 55022; EN 61000-3-2; EN 61000-4 compliance
- UV HM600 with EBM cabinet
> Ballast type : High efficiency electronic ballast SATEPA type
> Lamp cable : 1,5 mt
> Power supply : 230 Vac ± 10%
> Lamp drive : Single lamp drive
> Number of lamps : 8 lamps Max selectable
> Display : 2x8 characters LCD display
> Lamp monitoring : Counter for total and partial hours
> Displayed alarms : Lamps fault ; lamps end of life ; Sensor fault if provided
> Alarms available : Free contact relay
> Input controls : Remote ON/OFF
> Optional features: Sensor control (UV Irradiation / Temperature)
> Optional alarm : Audible beeper
> Ballast type : High efficiency electronic ballast SATEPA type
> Lamp cable : 1,5 mt
> Power supply : 230 Vac ± 10%
> Lamp drive : Single lamp drive
> Number of lamps : 16 lamps Max selectable
> Display : 2x12 characters LCD display
> Lamp monitoring : Counter for total and partial hours
> Displayed alarms : Lamps fault ; lamps end of life ; Sensor fault if provided ; customuzable alarm
> Alarms available : Free contact relay
> Input controls : Standard sensor or certified sensor ( O_Norm / DVGW ) ; customizable input
> Optional features: Sensor control (UV Irradiation / Temperature)
> Optional alarm : Audible beeper
> Optional outputs: 4-20 mA for sensor signal