MONO Series
DOMESTIC and POINT OF USE application
1,2 .. 5,0 m3/hr – 5,3 .. 22,00 GPM
Against: Cryptosporidium, Giardia, E.Coli and Fecal Coliform.
High efficiency low pressure UV-C lamp (9.000 hours lifespan)
High quality quarts sleeves
“A” basic electronic ballast plug or through cable
“D” smart LCD display logic UV³
AISI 304 standard reactor, AISI 316 optional
UV Irradiance and Temperature sensor optional
> 30 mJ/cm2 Max flow rate : 1,5 m3/hr - 6,60 GPM
> 40 mJ/cm2 Max flow rate : 1,2 m3/hr - 5,28 GPM
> Lamp type : 1 x 30W UV-C low pressure lamp 9.000 hr
> Chamber size : H 520mm ; Ø 60mm
> Connection : ¾" theraded male
> Optional : Sensor for temperature and UV irradiation ("D" series only)
> UVC30A - Led adaptor ballast version
> UVC30D3 - LCD control panel with UV³ logic controller version
> 30 mJ/cm2 Max flow rate : 2,8 m3/hr - 12,30 GPM
> 40 mJ/cm2 Max flow rate : 2,4 m3/hr - 10,60 GPM
> Lamp type : 1 x 40W UV-C low pressure lamp 9.000 hr
> Chamber size : H 935mm ; Ø 60mm
> Connection : 1" theraded male
> Optional : Sensor for temperature and UV irradiation ("D" series only)
> UVC40A - Led adaptor ballast version
> UVC40D3 - LCD control panel with UV³ logic controller version
> 30 mJ/cm2 Max flow rate : 6,0 m3/hr - 16,40 GPM
> 40 mJ/cm2 Max flow rate : 5,0 m3/hr - 22,00 GPM
> Lamp type : 1 x 80W UV-C low pressure lamp 9.000 hr
> Chamber size : H 935mm ; Ø 60mm
> Connection : 1 ¼" theraded male
> Optional : Sensor for temperature and UV irradiation
> UVC65D3 - LCD control panel with UV³ logic controller version
> 30 mJ/cm2 Max flow rate : 12,0 m3/hr - 52,80 GPM
> 40 mJ/cm2 Max flow rate : 9,0 m3/hr - 39,60 GPM
> Lamp type : 2 x 80W UV-C low pressure lamp 9.000 hr
> Chamber size : H 930mm ; Ø 114mm
> Connection : 1 ½" theraded male
> Optional : Sensor for temperature and UV irradiation
> UVC80D3 - LCD control panel with UV³ logic controller version
> Ballast type : Plug ballast
> Lamp cable : 1,5 mt
> Power supply : 90 to 240 Vac
> Lamp drive : High efficiency lamp drive
> Lamp monitoring : Green/red led for lamp status
> Optional cable layout : Through cable version available
> Optional alarm : Audible beeper
> Ballast type : LCD cabinet ballast
> Lamp cable : 1,5 mt
> Power supply : 230 Vac ± 10%
> Lamp drive : High efficiency electronic ballas
> Number of lamps managed: 2 lamps max selectable
> Display: 2x8 characters LCD display
> Lamp monitoring : Counter for total and partial hours lamp fault
> Displayed alarms: Lamps fsult; lasmp end of life;
> Alarms on board : Feee contact relay; Powered relay
> Input controls : Water flow switch; remote ON/OFF
> Optional features : Sensor control (UV Irradiation/Tempersature)
> Optional alarm : Audible beeper