POOL  Series

Application   RESIDENTIAL  POOL and SPA

11,0 .. 22,0 m3/hr    –   48,4 .. 96,9 GPM

Effective for breaking down combined chlorine

Initial UV dose 25.000 µWsec/cm3 – 30.000 µWsec/cm3  

LED pool controller   – Controller  UV3  with LCD display

High efficiency vapour mercury UV-C lamps (9.000 hours lifespan)

End of lamps life monitoring 

High quality quartz sleeves

Reactor SS AISI 304 / AISI 316

Irradiance and temperature sensor  optional

Flanged I/O optional

> Max flow rate : 11,0 m3/hr – 48,4 GPM with initial Dose 30 mJ/cm2

> Lamp type : 1 x 40W   UV-C low pressure lamp 9.000 hr

> Chamber size : H 935mm ; Ø 114 / 140 mm

> Flow switch :  Optional for lamp management

> Connection :  1½"  theraded male

> Optional : Sensor for temperature and UV irradiation 

> L11 - POOL - SS AISI 316 sterilizer with UV³ control logic

> HE L11 - POOL - HDPE sterilizer with UV³ control logic

> Max flow rate : 16,0 m3/hr – 70,4  GPM with initial Dose 30 mJ/cm2

> Lamp type : 1 x 80W   UV-C low pressure lamp 9.000 hr

> Chamber size : H 935mm ; Ø 114 / 140 mm

> Flow switch :  Optional for lamp management

> Connection :  1½"  theraded male

> Optional : Sensor for temperature and UV irradiation 

> L16 - POOL - SS AISI 316 sterilizer with UV³ control logic

> HE L16 - POOL - HDPE  sterilizer with UV³ control logic

> Max flow rate : 22,0 m3/hr – 97,0 GPM with initial Dose 30 mJ/cm2

> Lamp type : 2 x 80W   UV-C low pressure lamp 9.000 hr

> Chamber size : H 935mm ; Ø 140 / 180 mm

> Flow switch :  Optional for lamp management

> Connection :  1½"  theraded male

> Optional : Sensor for temperature and UV irradiation 

> L22 - POOL - SS AISI 316 sterilizer with UV³ control logic

> HE L22 - POOL - HDPE sterilizer with UV³ control logic

> Ballast type : LCD cabinet ballast

> Lamp cable : 1,5 mt

> Power supply : 230 Vac ± 10%

> Lamp drive : High efficiency electronic ballast

> Number of lamps : 2 lamps Max selectable

> Display : 2x8 characters LCD display

> Lamp monitoring : Counter for total and partial hours

> Displayed alarms : Lamps fault ; lamps end of life

> Alarms available : Free contact relay ; powered relay ; lamps end of life

> Flow control : Input water flow switch signal

> Optional features: Sensor control (UV Irradiation / Tmeperature)

> Optional alarm : Audible beeper